Jsme tu pro Vás
		Nevíte si s něčím rady? 
		Neváhejte nás kontaktovat.
	
		ABELman
Moje ABEL podpora
												
													Aruba 6000 48G Class4 PoE 4SFP 370W Switch
Parametry
Aruba 6000 48G Class4 PoE 4SFP 370W Switch
| 
 Specifications  | 
|
| 
 Aruba 6000 48G 4SFP Switch (R8N86A)  | 
|
| 
 Description  | 
 48x ports 10/100/1000BASE-T Ports 
 4x 1G/10G SFP ports 1x USB-C Console Port 1x USB Type-A Host port  | 
| 
 Power supplies  | 
 Fixed power supply  | 
| 
 Fans  | 
 Fixed fans  | 
| 
 Physical characteristics  | 
|
| 
 Dimensions  | 
 (H) 4.39 cm (W) 44.2 cm (D) 24.74 cm (1.73" x 17.4" x 9.74")  | 
| 
 Configuration Weight  | 
 3.42 kg (7.54 lbs)  | 
| 
 Additional Specifications  | 
|
| 
 CPU  | 
 Dual Core ARM Cortex A9 @ 1016 Mhz  | 
| 
 Memory and Flash  | 
 4 GB DDR3 16 GB eMMC  | 
| 
 Packet Buffer  | 
 12.38MB (4.5MB Ingress/7.875MB Egress)  | 
| 
 Performance  | 
|
| 
 Model Switching Capacity  | 
 104 Gbps  | 
| 
 Model Throughput Capacity  | 
 77.3 Mpps  | 
| 
 Average Latency (LIFO-64- bytes packets)  | 
 1 Gbps: 1.9 µSec  | 
| 
 Switched Virtual Interfaces (dual stack)  | 
 16  | 
| 
 IPv4 Host Table (ARP)  | 
 1,024  | 
| 
 IPv6 Host Table (ND)  | 
 512  | 
| 
 IPv4 Unicast Routes  | 
 512  | 
| 
 IPv6 Unicast Routes  | 
 512  | 
| 
 MAC Table Capacity  | 
 8,192  | 
| 
 IGMP Groups  | 
 512  | 
| 
 MLD Groups  | 
 512  | 
| 
 IPv4/IPv6/MAC ACL Entries (ingress)  | 
 256 / 128 / 256  | 
| 
 Aruba 6000 48G Class4 PoE 4SFP 370W Switch (R8N85A)  | 
 Aruba 6000 48G 4SFP Switch (R8N86A)  | 
 Aruba 6000 24G Class4 PoE 4SFP 370W Switch (R8N87A)  | 
|
| 
 Environment  | 
|||
| 
 Operating Temperature  | 
 32°F to 113°F (0°C to 45°C) up to 5000 ft (1.5 km) derate -1°C for every 1000 ft (305 m) from 5000 ft (1.5 km) to 10000 ft (3.0 km)  | 
 32°F to 113°F (0°C to 45°C) up to 5000 ft (1.5 km) derate -1°C for every 1000 ft (305 m) from 5000 ft (1.5 km) to 10000 ft (3.0 km)  | 
 32°F to 113°F (0°C to 45°C) up to 5000 ft (1.5 km) derate -1°C for every 1000 ft (305 m) from 5000 ft (1.5 km) to 10000 ft (3.0 km)  | 
| 
 Operating Relative Humidity  | 
 15% to 95% at 104°F (40°C) non-condensing  | 
 15% to 95% at 104°F (40°C) non-condensing  | 
 15% to 95% at 104°F (40°C) non-condensing  | 
| 
 Non-Operating  | 
 -40°F to 158°F (-40°C to 70°C) up to 15000 ft (4.6 km)  | 
 -40°F to 158°F (-40°C to 70°C) up to 15000 ft (4.6 km)  | 
 -40°F to 158°F (-40°C to 70°C) up to 15000 ft (4.6 km)  | 
| 
 Non-Operating Storage Relative Humidity  | 
 15% to 90% @ 149°F (65°C) non-condensing  | 
 15% to 90% @ 149°F (65°C) non-condensing  | 
 15% to 90% @ 149°F (65°C) non-condensing  | 
| 
 Max Operating Altitude  | 
 10000 feet (3 km) Max  | 
 10000 feet (3 km) Max  | 
 10000 feet (3 km) Max  | 
| 
 Max Non-Operating Altitude  | 
 15000 feet (4.6 km) Max  | 
 15000 feet (4.6 km) Max  | 
 15000 feet (4.6 km) Max  | 
| 
 Acoustic  | 
 Sound Power, LWAd = 4.3 Bel Sound Pressure, LpAm (Bystander) = 29.8 dB  | 
 Sound Power, LWAd = 3.6 Bel Sound Pressure, LpAm (Bystander)= 24.6 dB  | 
 Sound Power, LWAd = 3.9 Bel Sound Pressure, LpAm (Bystander)= 24.3 dB  | 
| 
 Primary Airflow  | 
 Side-to-side  | 
 Side-to-side  | 
 Side-to-side  | 
| 
 Electrical Characteristics  | 
|||
| 
 Frequency  | 
 50 / 60 Hz  | 
 50 / 60 Hz  | 
 50 / 60 Hz  | 
| 
 AC Voltage  | 
 100-127 VAC / 200-240 VAC  | 
 100-127 VAC / 200-240 VAC  | 
 100-127 VAC / 200-240 VAC  | 
| 
 Current  | 
 4.9 A / 2.4 A  | 
 0.8 A / 0.5 A  | 
 4.6 A / 2.3 A  | 
| 
 Power Consumption (230 VAC)  | 
 Idle: 30.6W Max Power (w/o PoE): 45W Max Power (w/ PoE): 480W  | 
 Idle: 20.6W Max Power (w/o PoE): 44.2W  | 
 Idle: 22.9W Max Power (w/o PoE): 32.7W Max Power (w/ PoE): 455W  | 
| 
 Safety  | 
 UL 60950-1; IEC 60950-1; EN 60950-1; CAN/ CSA-C22.2 No. 60950-1; EN 60825-1 UL 62368-1 Ed. 2; IEC 62368-1 Ed. 2; EN 62368-1:2014  | 
 UL 60950-1; IEC 60950-1; EN 60950-1; CAN/ CSA-C22.2 No. 60950-1; EN 60825-1 UL 62368-1 Ed. 2; IEC 62368-1 Ed. 2; EN 62368-1:2014  | 
 UL 60950-1; IEC 60950-1; EN 60950-1; CAN/ CSA-C22.2 No. 60950-1; EN 60825-1 UL 62368-1 Ed. 2; IEC 62368-1 Ed. 2; EN 62368-1:2014  | 
| 
 Emissions  | 
 VCCI-CISPR 32, Class A; CNS 13438; ICES-003 Issue 6 Class A; FCC CFR 47 Part 15, Class A; EN 55032: 2015 +AC:2016 / CISPR-32, Class A  | 
 VCCI-CISPR 32, Class A; CNS 13438; ICES-003 Issue 6 Class A; FCC CFR 47 Part 15, Class A; EN 55032: 2015 +AC:2016 / CISPR-32, Class A  | 
 VCCI-CISPR 32, Class A; CNS 13438; ICES-003 Issue 6 Class A; FCC CFR 47 Part 15, Class A; EN 55032: 2015 +AC:2016 / CISPR-32, Class A  | 
| 
 Aruba 6000 48G Class4 PoE 4SFP 370W Switch (R8N85A)  | 
 Aruba 6000 48G 4SFP Switch (R8N86A)  | 
 Aruba 6000 24G Class4 PoE 4SFP 370W Switch (R8N87A)  | 
|
| 
 Lasers  | 
 EN 60825-1:2007 / IEC 60825- 1:2007 Class 1 Class 1 Laser Products / Laser Klasse 1 (Applicable for accessories - Optical Transceivers only)  | 
 EN 60825-1:2007 / IEC 60825- 1:2007 Class 1 Class 1 Laser Products / Laser Klasse 1 (Applicable for accessories - Optical Transceivers only)  | 
 EN 60825-1:2007 / IEC 60825- 1:2007 Class 1 Class 1 Laser Products / Laser Klasse 1 (Applicable for accessories - Optical Transceivers only)  | 
| 
 Immunity  | 
|||
| 
 Generic  | 
 CISPR 24 / CISPR 35  | 
 CISPR 24 / CISPR 35  | 
 CISPR 24 / CISPR 35  | 
| 
 EN  | 
 EN 55024:2010 / EN 55035:2017  | 
 EN 55024:2010 / EN 55035:2017  | 
 EN 55024:2010 / EN 55035:2017  | 
| 
 ESD  | 
 IEC 61000-4-2  | 
 IEC 61000-4-2  | 
 IEC 61000-4-2  | 
| 
 Radiated  | 
 IEC 61000-4-3  | 
 IEC 61000-4-3  | 
 IEC 61000-4-3  | 
| 
 EFT/Burst  | 
 IEC 61000-4-4  | 
 IEC 61000-4-4  | 
 IEC 61000-4-4  | 
| 
 Surge  | 
 IEC 61000-4-5  | 
 IEC 61000-4-5  | 
 IEC 61000-4-5  | 
| 
 Conducted  | 
 IEC 61000-4-6  | 
 IEC 61000-4-6  | 
 IEC 61000-4-6  | 
| 
 Power frequency magnetic field  | 
 IEC 61000-4-8  | 
 IEC 61000-4-8  | 
 IEC 61000-4-8  | 
| 
 Voltage dips and interruptions  | 
 IEC 61000-4-11  | 
 IEC 61000-4-11  | 
 IEC 61000-4-11  | 
| 
 Harmonics  | 
 EN 61000-3-2, IEC 61000-3-2  | 
 EN 61000-3-2, IEC 61000-3-2  | 
 EN 61000-3-2, IEC 61000-3-2  | 
| 
 Flicker  | 
 EN 61000-3-3, IEC 61000-3-3  | 
 EN 61000-3-3, IEC 61000-3-3  | 
 EN 61000-3-3, IEC 61000-3-3  | 
| 
 Mounting and Enclosure  | 
 Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-mounting kit available); horizontal surface mounting; wall mounting  | 
 Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-mounting kit available); horizontal surface mounting; wall mounting  | 
 Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-mounting kit available); horizontal surface mounting; wall mounting  |